get_demand_results_file
- Path:
outputs/data/demand/B001.csv - File type:
csv - Created by:
demand - Used by:
decentralized,optimization,sewage_potential,thermal_network
| Variable | Description | Type | Unit | Values |
|---|---|---|---|---|
date | Time stamp for each day of the year ascending in hour intervals. | date | NA | YYYY-MM-DD |
E_sys_kWh | End-use total electricity consumption (system-level demand) = Ea + El + Edata + Epro + Eaux + Ev + Eve | float | [kWh] | {0.0…n} |
Ea_kWh | End-use electricity for appliances | float | [kWh] | {0.0…n} |
Eal_kWh | End-use electricity consumption of appliances and lighting, Eal = El_W + Ea_W | float | [kWh] | {0.0…n} |
Eaux_kWh | End-use auxiliary electricity consumption, Eaux = Eaux_fw + Eaux_ww + Eaux_cs + Eaux_hs + Ehs_lat_aux | float | [kWh] | {0.0…n} |
Edata_kWh | End-use data centre electricity consumption. | float | [kWh] | {0.0…n} |
El_kWh | End-use electricity for lights | float | [kWh] | {0.0…n} |
Epro_kWh | End-use electricity consumption for industrial processes. | float | [kWh] | {0.0…n} |
Ev_kWh | End-use electricity for electric vehicles | float | [kWh] | {0.0…n} |
Eve_kWh | End-use electricity for ventilation | float | [kWh] | {0.0…n} |
I_rad_kWh | Radiative heat loss | float | [kWh] | {0.0…n} |
I_sol_and_I_rad_kWh | Net radiative heat gain | float | [kWh] | {0.0…n} |
I_sol_kWh | Solar heat gain | float | [kWh] | {0.0…n} |
mcpcdata_sys_kWperC | Capacity flow rate (mass flow* specific heat capacity) of the chilled water delivered to data centre. | float | [kW/C] | {0.0…n} |
mcpcre_sys_kWperC | Capacity flow rate (mass flow* specific heat Capacity) of the chilled water delivered to refrigeration. | float | [kW/C] | {0.0…n} |
mcpcs_sys_ahu_kWperC | Capacity flow rate (mass flow* specific heat Capacity) of the chilled water delivered to air handling units (space cooling). | float | [kW/C] | {0.0…n} |
mcpcs_sys_aru_kWperC | Capacity flow rate (mass flow* specific heat Capacity) of the chilled water delivered to air recirculation units (space cooling). | float | [kW/C] | {0.0…n} |
mcpcs_sys_kWperC | Capacity flow rate (mass flow* specific heat Capacity) of the chilled water delivered to space cooling. | float | [kW/C] | {0.0…n} |
mcpcs_sys_scu_kWperC | Capacity flow rate (mass flow* specific heat Capacity) of the chilled water delivered to sensible cooling units (space cooling). | float | [kW/C] | {0.0…n} |
mcphs_sys_ahu_kWperC | Capacity flow rate (mass flow* specific heat Capacity) of the warm water delivered to air handling units (space heating). | float | [kW/C] | {0.0…n} |
mcphs_sys_aru_kWperC | Capacity flow rate (mass flow* specific heat Capacity) of the warm water delivered to air recirculation units (space heating). | float | [kW/C] | {0.0…n} |
mcphs_sys_kWperC | Capacity flow rate (mass flow* specific heat Capacity) of the warm water delivered to space heating. | float | [kW/C] | {0.0…n} |
mcphs_sys_shu_kWperC | Capacity flow rate (mass flow* specific heat Capacity) of the warm water delivered to sensible heating units (space heating). | float | [kW/C] | {0.0…n} |
mcptw_kWperC | Capacity flow rate (mass flow* specific heat capacity) of the fresh water | float | [kW/C] | {0.0…n} |
mcpww_sys_kWperC | Capacity flow rate (mass flow* specific heat capacity) of domestic hot water | float | [kW/C] | {0.0…n} |
name | Unique building ID. It must start with a letter. | string | NA | alphanumeric |
people | Predicted occupancy: number of people in building | int | [people] | {0…n} |
Q_gain_lat_peop_kWh | Latent heat gain from people | float | [kWh] | {0.0…n} |
Q_gain_sen_app_kWh | Sensible heat gain from appliances | float | [kWh] | {0.0…n} |
Q_gain_sen_base_kWh | Sensible heat gain from transmission through the base | float | [kWh] | {0.0…n} |
Q_gain_sen_data_kWh | Sensible heat gain from data centres | float | [kWh] | {0.0…n} |
Q_gain_sen_light_kWh | Sensible heat gain from lighting | float | [kWh] | {0.0…n} |
Q_gain_sen_peop_kWh | Sensible heat gain from people | float | [kWh] | {0.0…n} |
Q_gain_sen_pro_kWh | Sensible heat gain from industrial processes. | float | [kWh] | {0.0…n} |
Q_gain_sen_roof_kWh | Sensible heat gain from transmission through the roof | float | [kWh] | {0.0…n} |
Q_gain_sen_vent_kWh | Sensible heat gain from ventilation and infiltration | float | [kWh] | {0.0…n} |
Q_gain_sen_wall_kWh | Sensible heat gain from transmission through the walls | float | [kWh] | {0.0…n} |
Q_gain_sen_wind_kWh | Sensible heat gain from transmission through the windows | float | [kWh] | {0.0…n} |
Q_loss_sen_ref_kWh | Sensible heat loss from refrigeration systems | float | [kWh] | {0.0…n} |
QC_sys_kWh | Total end-use cooling demand (system-level), QC_sys = Qcs_sys + Qcdata_sys + Qcre_sys + Qcpro_sys | float | [kWh] | {0.0…n} |
Qcdata_kWh | Data centre space cooling demand | float | [kWh] | {0.0…n} |
Qcdata_sys_kWh | End-use data center cooling demand | float | [kWh] | {0.0…n} |
Qcpro_sys_kWh | Process cooling demand | float | [kWh] | {0.0…n} |
Qcre_kWh | Refrigeration space cooling demand | float | [kWh] | {0.0…n} |
Qcre_sys_kWh | End-use refrigeration demand | float | [kWh] | {0.0…n} |
Qcs_dis_ls_kWh | Cooling system distribution losses | float | [kWh] | {0.0…n} |
Qcs_em_ls_kWh | Cooling system emission losses | float | [kWh] | {0.0…n} |
Qcs_kWh | Useful energy for space cooling (thermal demand at point of use) | float | [kWh] | {0.0…n} |
Qcs_lat_ahu_kWh | AHU latent cooling demand | float | [kWh] | {0.0…n} |
Qcs_lat_aru_kWh | ARU latent cooling demand | float | [kWh] | {0.0…n} |
Qcs_lat_sys_kWh | Total latent cooling demand for all systems | float | [kWh] | {0.0…n} |
Qcs_sen_ahu_kWh | AHU sensible cooling demand | float | [kWh] | {0.0…n} |
Qcs_sen_aru_kWh | ARU sensible cooling demand | float | [kWh] | {0.0…n} |
Qcs_sen_scu_kWh | SHU sensible cooling demand | float | [kWh] | {0.0…n} |
Qcs_sen_sys_kWh | Total sensible cooling demand for all systems | float | [kWh] | {0.0…n} |
Qcs_sys_ahu_kWh | AHU system cooling demand | float | [kWh] | {0.0…n} |
Qcs_sys_aru_kWh | ARU system cooling demand | float | [kWh] | {0.0…n} |
Qcs_sys_kWh | End-use space cooling demand (system-level including HVAC losses), Qcs_sys = Qcs_sen_sys + Qcs_lat_sys + Qcs_em_ls + Qcs_dis_ls | float | [kWh] | {0.0…n} |
Qcs_sys_scu_kWh | SCU system cooling demand | float | [kWh] | {0.0…n} |
QH_sys_kWh | Total end-use heating demand (system-level), QH_sys = Qww_sys + Qhs_sys + Qhpro_sys | float | [kWh] | {0.0…n} |
Qhpro_sys_kWh | Process heating demand | float | [kWh] | {0.0…n} |
Qhs_dis_ls_kWh | Heating system distribution losses | float | [kWh] | {0.0…n} |
Qhs_em_ls_kWh | Heating system emission losses | float | [kWh] | {0.0…n} |
Qhs_kWh | Useful energy for space heating (thermal demand at point of use) | float | [kWh] | {0.0…n} |
Qhs_lat_ahu_kWh | AHU latent heating demand | float | [kWh] | {0.0…n} |
Qhs_lat_aru_kWh | ARU latent heating demand | float | [kWh] | {0.0…n} |
Qhs_lat_sys_kWh | Total latent heating demand for all systems | float | [kWh] | {0.0…n} |
Qhs_sen_ahu_kWh | AHU sensible heating demand | float | [kWh] | {0.0…n} |
Qhs_sen_aru_kWh | ARU sensible heating demand | float | [kWh] | {0.0…n} |
Qhs_sen_shu_kWh | SHU sensible heating demand | float | [kWh] | {0.0…n} |
Qhs_sen_sys_kWh | Total sensible heating demand | float | [kWh] | {0.0…n} |
Qhs_sys_ahu_kWh | Space heating demand in AHU | float | [kWh] | {0.0…n} |
Qhs_sys_aru_kWh | Space heating demand in ARU | float | [kWh] | {0.0…n} |
Qhs_sys_kWh | End-use space heating demand (system-level including HVAC losses), Qhs_sys = Qhs_sen_sys + Qhs_em_ls + Qhs_dis_ls | float | [kWh] | {0.0…n} |
Qhs_sys_shu_kWh | SHU system heating demand | float | [kWh] | {0.0…n} |
Qww_kWh | Useful energy for domestic hot water (thermal demand at taps) | float | [kWh] | {0.0…n} |
Qww_sys_kWh | End-use domestic hot water demand (system-level including distribution losses) | float | [kWh] | {0.0…n} |
T_ext_C | Outdoor temperature | float | [C] | {0.0…n} |
T_int_C | Indoor temperature | float | [C] | {0.0…n} |
Tcdata_sys_re_C | Cooling supply temperature of the data centre | float | [C] | {0.0…n} |
Tcdata_sys_sup_C | Cooling return temperature of the data centre | float | [C] | {0.0…n} |
Tcre_sys_re_C | Cooling return temperature of the refrigeration system. | float | [C] | {0.0…n} |
Tcre_sys_sup_C | Cooling supply temperature of the refrigeration system. | float | [C] | {0.0…n} |
Tcs_sys_re_ahu_C | Return temperature cooling system | float | [C] | {0.0…n} |
Tcs_sys_re_aru_C | Return temperature cooling system | float | [C] | {0.0…n} |
Tcs_sys_re_C | System cooling return temperature. | float | [C] | {0.0…n} |
Tcs_sys_re_scu_C | Return temperature cooling system | float | [C] | {0.0…n} |
Tcs_sys_sup_ahu_C | Supply temperature cooling system | float | [C] | {0.0…n} |
Tcs_sys_sup_aru_C | Supply temperature cooling system | float | [C] | {0.0…n} |
Tcs_sys_sup_C | System cooling supply temperature. | float | [C] | {0.0…n} |
Tcs_sys_sup_scu_C | Supply temperature cooling system | float | [C] | {0.0…n} |
theta_o_C | Operative temperature in building (RC-model) used for comfort plotting | float | [C] | {0.0…n} |
Ths_sys_re_ahu_C | Return temperature heating system | float | [C] | {0.0…n} |
Ths_sys_re_aru_C | Return temperature heating system | float | [C] | {0.0…n} |
Ths_sys_re_C | Heating system return temperature. | float | [C] | {0.0…n} |
Ths_sys_re_shu_C | Return temperature heating system | float | [C] | {0.0…n} |
Ths_sys_sup_ahu_C | Supply temperature heating system | float | [C] | {0.0…n} |
Ths_sys_sup_aru_C | Supply temperature heating system | float | [C] | {0.0…n} |
Ths_sys_sup_C | Heating system supply temperature. | float | [C] | {0.0…n} |
Ths_sys_sup_shu_C | Supply temperature heating system | float | [C] | {0.0…n} |
Tww_sys_re_C | Return temperature hotwater system | float | [C] | {0.0…n} |
Tww_sys_sup_C | Supply temperature hotwater system | float | [C] | {0.0…n} |
x_int | Internal mass fraction of humidity (water/dry air) | float | [kg/kg] | {0.0…n} |
get_occupancy_model_file
- Path:
outputs/data/occupancy/B001.csv - File type:
csv - Created by:
occupancy - Used by:
demand
| Variable | Description | Type | Unit | Values |
|---|---|---|---|---|
DATE | Time stamp for each day of the year ascending in hourly intervals | date | NA | YYYY-MM-DD |
Ea_W | Electrical load due to processes | float | [Wh] | {0.0…n} |
Ed_W | Electrical load due to servers/data centers | float | [Wh] | {0.0…n} |
El_W | Electrical load due to lighting | float | [Wh] | {0.0…n} |
Epro_W | Electrical load due to processes | float | [Wh] | {0.0…n} |
people_p | Number of people in the building | float | [-] | {0.0…n} |
Qcpro_W | Process cooling load | float | [Wh] | {0.0…n} |
Qcre_W | Cooling load due to cool room refrigeration | float | [Wh] | {0.0…n} |
Qhpro_W | Process heat load | float | [Wh] | {0.0…n} |
Qs_W | Sensible heat load of people | float | [Wh] | {0.0…n} |
Tcs_set_C | Set point temperature of space cooling system | string | [...C] | alphanumeric |
Ths_set_C | Set point temperature of space heating system | string | [...C] | alphanumeric |
Ve_lps | Ventilation rate | float | [L] | {0.0…n} |
Vw_lph | Fresh water consumption (includes cold and hot water) | float | [L] | {0.0…n} |
Vww_lph | Domestic hot water consumption | float | [L] | {0.0…n} |
X_gh | Moisture released by occupants | float | [g] | {0.0…n} |
get_total_demand
- Path:
outputs/data/demand/Total_demand.csv - File type:
csv - Created by:
demand - Used by:
decentralized,emissions,network_layout,system_costs,optimization,sewage_potential,thermal_network
| Variable | Description | Type | Unit | Values |
|---|---|---|---|---|
Af_m2 | Conditioned floor area (heated/cooled) | float | [m2] | {0.0…n} |
Aocc_m2 | Occupied floor area (heated/cooled) | float | [m2] | {0.0…n} |
Aroof_m2 | Roof area | float | [m2] | {0.0…n} |
E_sys0_kW | Nominal end-use electricity demand | float | [kW] | {0.0…n} |
E_sys_MWhyr | End-use total electricity consumption (system-level demand), E_sys = Eve + Ea + El + Edata + Epro + Eaux + Ev | float | [MWh/yr] | {0.0…n} |
Ea0_kW | Nominal end-use electricity for appliances | float | [kW] | {0.0…n} |
Ea_MWhyr | End-use electricity for appliances | float | [MWh/yr] | {0.0…n} |
Eal0_kW | Nominal Total net electricity for all sources and sinks. | float | [kW] | {0.0…n} |
Eal_MWhyr | End-use electricity consumption of appliances and lighting, Eal = El_W + Ea_W | float | [MWh/yr] | {0.0…n} |
Eaux0_kW | Nominal Auxiliary electricity consumption. | float | [kW] | {0.0…n} |
Eaux_MWhyr | End-use auxiliary electricity consumption, Eaux = Eaux_fw + Eaux_ww + Eaux_cs + Eaux_hs + Ehs_lat_aux | float | [MWh/yr] | {0.0…n} |
Edata0_kW | Nominal Data centre electricity consumption. | float | [kW] | {0.0…n} |
Edata_MWhyr | Electricity consumption for data centers | float | [MWh/yr] | {0.0…n} |
El0_kW | Nominal end-use electricity for lights | float | [kW] | {0.0…n} |
El_MWhyr | End-use electricity for lights | float | [MWh/yr] | {0.0…n} |
Epro0_kW | Nominal Industrial processes electricity consumption. | float | [kW] | {0.0…n} |
Epro_MWhyr | Electricity supplied to industrial processes | float | [MWh/yr] | {0.0…n} |
Ev0_kW | Nominal end-use electricity for electric vehicles | float | [kW] | {0.0…n} |
Ev_MWhyr | End-use electricity for electric vehicles | float | [MWh/yr] | {0.0…n} |
Eve0_kW | Nominal end-use electricity for ventilation | float | [kW] | {0.0…n} |
Eve_MWhyr | End-use electricity for ventilation | float | [MWh/yr] | {0.0…n} |
GFA_m2 | Gross floor area | float | [m2] | {0.0…n} |
name | Unique building ID. It must start with a letter. | string | NA | alphanumeric |
people0 | Nominal occupancy | int | [people] | {0…n} |
QC_sys0_kW | Nominal Total system cooling demand. | float | [kW] | {0.0…n} |
QC_sys_MWhyr | Total end-use cooling demand (system-level), QC_sys = Qcs_sys + Qcdata_sys + Qcre_sys + Qcpro_sys | float | [MWh/yr] | {0.0…n} |
Qcdata0_kW | Nominal Data centre cooling demand. | float | [kW] | {0.0…n} |
Qcdata_MWhyr | Data centre cooling demand | float | [MWh/yr] | {0.0…n} |
Qcdata_sys0_kW | Nominal end-use data center cooling demand | float | [kW] | {0.0…n} |
Qcdata_sys_MWhyr | End-use data center cooling demand | float | [MWh/yr] | {0.0…n} |
Qcpro_sys0_kW | Nominal process cooling demand. | float | [kW] | {0.0…n} |
Qcpro_sys_MWhyr | Yearly processes cooling demand. | float | [MWh/yr] | {0.0…n} |
Qcre0_kW | Nominal Refrigeration cooling demand. | float | [kW] | {0.0…n} |
Qcre_MWhyr | Refrigeration cooling demand for the system | float | [MWh/yr] | {0.0…n} |
Qcre_sys0_kW | Nominal refrigeration cooling demand | float | [kW] | {0.0…n} |
Qcre_sys_MWhyr | End-use refrigeration demand | float | [MWh/yr] | {0.0…n} |
Qcs0_kW | Nominal Total cooling demand. | float | [kW] | {0.0…n} |
Qcs_dis_ls0_kW | Nominal Cooling distribution losses. | float | [kW] | {0.0…n} |
Qcs_dis_ls_MWhyr | Cooling distribution losses | float | [MWh/yr] | {0.0…n} |
Qcs_em_ls0_kW | Nominal Cooling emission losses. | float | [kW] | {0.0…n} |
Qcs_em_ls_MWhyr | Cooling emission losses | float | [MWh/yr] | {0.0…n} |
Qcs_lat_ahu0_kW | Nominal AHU latent cooling demand. | float | [kW] | {0.0…n} |
Qcs_lat_ahu_MWhyr | AHU latent cooling demand | float | [MWh/yr] | {0.0…n} |
Qcs_lat_aru0_kW | Nominal ARU latent cooling demand. | float | [kW] | {0.0…n} |
Qcs_lat_aru_MWhyr | ARU latent cooling demand | float | [MWh/yr] | {0.0…n} |
Qcs_lat_sys0_kW | Nominal System latent cooling demand. | float | [kW] | {0.0…n} |
Qcs_lat_sys_MWhyr | Latent cooling demand | float | [MWh/yr] | {0.0…n} |
Qcs_MWhyr | Useful energy for space cooling (thermal demand at point of use) | float | [MWh/yr] | {0.0…n} |
Qcs_sen_ahu0_kW | Nominal AHU system cooling demand. | float | [kW] | {0.0…n} |
Qcs_sen_ahu_MWhyr | AHU system cooling demand | float | [MWh/yr] | {0.0…n} |
Qcs_sen_aru0_kW | Nominal ARU system cooling demand. | float | [kW] | {0.0…n} |
Qcs_sen_aru_MWhyr | ARU system cooling demand | float | [MWh/yr] | {0.0…n} |
Qcs_sen_scu0_kW | Nominal SCU system cooling demand. | float | [kW] | {0.0…n} |
Qcs_sen_scu_MWhyr | SCU system cooling demand | float | [MWh/yr] | {0.0…n} |
Qcs_sen_sys0_kW | Nominal Sensible system cooling demand. | float | [kW] | {0.0…n} |
Qcs_sen_sys_MWhyr | Sensible system cooling demand | float | [MWh/yr] | {0.0…n} |
Qcs_sys0_kW | Nominal end-use space cooling demand | float | [kW] | {0.0…n} |
Qcs_sys_ahu0_kW | Nominal AHU system cooling demand. | float | [kW] | {0.0…n} |
Qcs_sys_ahu_MWhyr | AHU system cooling demand | float | [MWh/yr] | {0.0…n} |
Qcs_sys_aru0_kW | Nominal ARU system cooling demand. | float | [kW] | {0.0…n} |
Qcs_sys_aru_MWhyr | ARU system cooling demand | float | [MWh/yr] | {0.0…n} |
Qcs_sys_MWhyr | End-use space cooling demand (system-level including HVAC losses), Qcs_sys = Qcs_sen_sys + Qcs_lat_sys + Qcs_em_ls + Qcs_dis_ls | float | [MWh/yr] | {0.0…n} |
Qcs_sys_scu0_kW | Nominal SCU system cooling demand. | float | [kW] | {0.0…n} |
Qcs_sys_scu_MWhyr | SCU system cooling demand | float | [MWh/yr] | {0.0…n} |
QH_sys0_kW | Nominal total building heating demand. | float | [kW] | {0.0…n} |
QH_sys_MWhyr | Total end-use heating demand (system-level) | float | [MWh/yr] | {0.0…n} |
Qhpro_sys0_kW | Nominal process heating demand. | float | [kW] | {0.0…n} |
Qhpro_sys_MWhyr | Yearly processes heating demand. | float | [MWh/yr] | {0.0…n} |
Qhs0_kW | Nominal Total heating demand. | float | [kW] | {0.0…n} |
Qhs_dis_ls0_kW | Nominal Heating system distribution losses. | float | [kW] | {0.0…n} |
Qhs_dis_ls_MWhyr | Heating system distribution losses | float | [MWh/yr] | {0.0…n} |
Qhs_em_ls0_kW | Nominal Heating emission losses. | float | [kW] | {0.0…n} |
Qhs_em_ls_MWhyr | Heating system emission losses | float | [MWh/year] | {0.0…n} |
Qhs_lat_ahu0_kW | Nominal AHU latent heating demand. | float | [kW] | {0.0…n} |
Qhs_lat_ahu_MWhyr | AHU latent heating demand | float | [MWh/yr] | {0.0…n} |
Qhs_lat_aru0_kW | Nominal ARU latent heating demand. | float | [kW] | {0.0…n} |
Qhs_lat_aru_MWhyr | ARU latent heating demand | float | [MWh/yr] | {0.0…n} |
Qhs_lat_sys0_kW | Nominal System latent heating demand. | float | [kW] | {0.0…n} |
Qhs_lat_sys_MWhyr | System latent heating demand | float | [MWh/yr] | {0.0…n} |
Qhs_MWhyr | Useful energy for space heating (thermal demand at point of use) | float | [MWh/yr] | {0.0…n} |
Qhs_sen_ahu0_kW | Nominal AHU sensible heating demand. | float | [kW] | {0.0…n} |
Qhs_sen_ahu_MWhyr | Sensible heating demand in AHU | float | [MWh/yr] | {0.0…n} |
Qhs_sen_aru0_kW | ARU sensible heating demand | float | [kW] | {0.0…n} |
Qhs_sen_aru_MWhyr | ARU sensible heating demand | float | [MWh/yr] | {0.0…n} |
Qhs_sen_shu0_kW | Nominal SHU sensible heating demand. | float | [kW] | {0.0…n} |
Qhs_sen_shu_MWhyr | SHU sensible heating demand | float | [MWh/yr] | {0.0…n} |
Qhs_sen_sys0_kW | Nominal HVAC systems sensible heating demand. | float | [kW] | {0.0…n} |
Qhs_sen_sys_MWhyr | Sensible heating demand | float | [MWh/yr] | {0.0…n} |
Qhs_sys0_kW | Nominal end-use space heating demand | float | [kW] | {0.0…n} |
Qhs_sys_ahu0_kW | Nominal AHU sensible heating demand. | float | [kW] | {0.0…n} |
Qhs_sys_ahu_MWhyr | AHU system heating demand | float | [MWh/yr] | {0.0…n} |
Qhs_sys_aru0_kW | Nominal ARU sensible heating demand. | float | [kW] | {0.0…n} |
Qhs_sys_aru_MWhyr | ARU sensible heating demand | float | [MWh/yr] | {0.0…n} |
Qhs_sys_MWhyr | End-use space heating demand (system-level including HVAC losses), Qhs_sys = Qhs_sen_sys + Qhs_em_ls + Qhs_dis_ls | float | [MWh/yr] | {0.0…n} |
Qhs_sys_shu0_kW | Nominal SHU sensible heating demand. | float | [kW] | {0.0…n} |
Qhs_sys_shu_MWhyr | SHU sensible heating demand | float | [MWh/yr] | {0.0…n} |
Qww0_kW | Nominal DHW heating demand. | float | [kW] | {0.0…n} |
Qww_MWhyr | Useful energy for domestic hot water (thermal demand at taps) | float | [MWh/yr] | {0.0…n} |
Qww_sys0_kW | Nominal end-use hotwater demand | float | [kW] | {0.0…n} |
Qww_sys_MWhyr | End-use domestic hot water demand (system-level including distribution losses) | float | [MWh/yr] | {0.0…n} |