get_geothermal_potentialget_sewage_heat_potentialget_water_body_potentialPV_metadata_resultsPV_resultsPV_total_buildingsPV_totalsPVT_metadata_resultsPVT_resultsPVT_total_buildingsPVT_totalsSC_metadata_resultsSC_resultsSC_total_buildingsSC_totals
get_geothermal_potential
- Path:
outputs/data/potentials/Shallow_geothermal_potential.csv - File type:
csv - Created by:
shallow_geothermal_potential - Used by:
optimization
| Variable | Description | Type | Unit | Values |
|---|---|---|---|---|
Area_avail_m2 | areas available to install ground source heat pumps | float | [m2] | {0.0…n} |
QGHP_kW | geothermal heat potential | float | [kW] | {0.0…n} |
Ts_C | ground temperature | float | [C] | {0.0…n} |
get_sewage_heat_potential
- Path:
outputs/data/potentials/Sewage_heat_potential.csv - File type:
csv - Created by:
sewage_potential - Used by:
optimization
| Variable | Description | Type | Unit | Values |
|---|---|---|---|---|
mww_zone_kWperC | heat capacity of total sewage in a zone | float | [kW/C] | {0.0…n} |
Qsw_kW | heat extracted from sewage flows | float | [kWh] | {0.0…n} |
T_in_HP_C | Inlet temperature of the sweage heapump | float | [C] | {0.0…n} |
T_in_sw_C | Inlet temperature of sewage flows | float | [C] | {0.0…n} |
T_out_HP_C | Outlet temperature of the sewage heatpump | float | [C] | {0.0…n} |
T_out_sw_C | Outlet temperature of sewage flows | float | [C] | {0.0…n} |
Ts_C | Average temperature of sewage flows | float | [C] | {0.0…n} |
get_water_body_potential
- Path:
outputs/data/potentials/Water_body_potential.csv - File type:
csv - Created by:
water_body_potential - Used by:
optimization
| Variable | Description | Type | Unit | Values |
|---|---|---|---|---|
QLake_kW | thermal potential from water body | float | [kWh] | {0.0…n} |
Ts_C | average temperature of the water body | float | [C] | {0.0…n} |
PV_metadata_results
- Path:
outputs/data/potentials/solar/B001_PV_sensors.csv - File type:
csv - Created by:
photovoltaic - Used by: (none)
| Variable | Description | Type | Unit | Values |
|---|---|---|---|---|
area_installed_module_m2 | The area of the building surface covered by one solar panel | float | [m2] | {0.0…n} |
AREA_m2 | Surface area. | float | [m2] | {0.0…n} |
array_spacing_m | Spacing between solar arrays. | float | [m] | {0.0…n} |
B_deg | Tilt angle of the installed solar panels | float | [deg] | {0.0…n} |
BUILDING | Unique building ID. It must start with a letter. | string | [-] | alphanumeric |
CATB | Category according to the tilt angle of the panel | int | [-] | {0…n} |
CATGB | Category according to the annual radiation on the panel surface | int | [-] | {0…n} |
CATteta_z | Category according to the surface azimuth of the panel | int | [-] | {0…n} |
intersection | flag to indicate whether this surface is intersecting with another surface (0: no intersection, 1: intersected) | int | [-] | {0, 1} |
orientation | Orientation of the surface (north/east/south/west/top) | string | [-] | {north, south, west, east, top} |
SURFACE | Unique surface ID for each building exterior surface. | string | [-] | alphanumeric |
surface | Unique surface ID for each building exterior surface. | string | [-] | alphanumeric |
surface_azimuth_deg | Azimuth angle of the panel surface e.g. south facing = 180 deg | float | [deg] | {0.0…n} |
tilt_deg | Tilt angle of roof or walls | float | [deg] | {0.0…n} |
total_rad_Whm2 | Total radiatiative potential of a given surfaces area. | float | [Wh/m2] | {0.0…n} |
TYPE | Surface typology. | string | [-] | {walls, roofs} |
type_orientation | Concatenated surface type and orientation. | string | [-] | {walls_east, walls_south, walls_north, walls_west, roofs_top} |
Xcoor | Describes the position of the x vector. | float | [-] | {0.0…n} |
Xdir | Directional scalar of the x vector. | float | [-] | {-1.0…1.0} |
Ycoor | Describes the position of the y vector. | float | [-] | {0.0…n} |
Ydir | Directional scalar of the y vector. | float | [-] | {-1.0…1.0} |
Zcoor | Describes the position of the z vector. | float | [-] | {0.0…n} |
Zdir | Directional scalar of the z vector. | float | [-] | {-1.0…1.0} |
PV_results
- Path:
outputs/data/potentials/solar/B001_PV.csv - File type:
csv - Created by:
photovoltaic - Used by: (none)
| Variable | Description | Type | Unit | Values |
|---|---|---|---|---|
Area_PV_m2 | Total area of investigated collector. | float | [m2] | {0.0…n} |
Date | Date and time in hourly steps. | date | NA | YYYY-MM-DD |
E_PV_gen_kWh | Total electricity generated by the collector. | float | [kWh] | {0.0…n} |
PV_roofs_top_E_kWh | Electricity production from photovoltaic panels on roof tops | float | [kWh] | {0.0…n} |
PV_roofs_top_m2 | Collector surface area on roof tops. | float | [m2] | {0.0…n} |
PV_walls_east_E_kWh | Electricity production from photovoltaic panels on east facades | float | [kWh] | {0.0…n} |
PV_walls_east_m2 | Collector surface area on east facades. | float | [m2] | {0.0…n} |
PV_walls_north_E_kWh | Electricity production from photovoltaic panels on north facades | float | [kWh] | {0.0…n} |
PV_walls_north_m2 | Collector surface area on north facades. | float | [m2] | {0.0…n} |
PV_walls_south_E_kWh | Electricity production from photovoltaic panels on south facades | float | [kWh] | {0.0…n} |
PV_walls_south_m2 | Collector surface area on south facades. | float | [m2] | {0.0…n} |
PV_walls_west_E_kWh | Electricity production from photovoltaic panels on west facades | float | [kWh] | {0.0…n} |
PV_walls_west_m2 | West facing wall collector surface area. | float | [m2] | {0.0…n} |
radiation_kWh | Total radiatiative potential. | float | [kWh] | {0.0…n} |
PV_total_buildings
- Path:
outputs/data/potentials/solar/PV_total_buildings.csv - File type:
csv - Created by:
photovoltaic - Used by: (none)
| Variable | Description | Type | Unit | Values |
|---|---|---|---|---|
Area_PV_m2 | Total area of investigated collector. | float | [m2] | {0.0…n} |
E_PV_gen_kWh | Total electricity generated by the collector. | float | [kWh] | {0.0…n} |
name | Unique building ID. It must start with a letter. | string | [-] | alphanumeric |
PV_roofs_top_E_kWh | Electricity production from photovoltaic panels on roof tops | float | [kWh] | {0.0…n} |
PV_roofs_top_m2 | Collector surface area on roof tops. | float | [m2] | {0.0…n} |
PV_walls_east_E_kWh | Electricity production from photovoltaic panels on east facades | float | [kWh] | {0.0…n} |
PV_walls_east_m2 | Collector surface area on east facades. | float | [m2] | {0.0…n} |
PV_walls_north_E_kWh | Electricity production from photovoltaic panels on north facades | float | [kWh] | {0.0…n} |
PV_walls_north_m2 | Collector surface area on north facades. | float | [m2] | {0.0…n} |
PV_walls_south_E_kWh | Electricity production from photovoltaic panels on south facades | float | [kWh] | {0.0…n} |
PV_walls_south_m2 | Collector surface area on south facades. | float | [m2] | {0.0…n} |
PV_walls_west_E_kWh | Electricity production from photovoltaic panels on west facades | float | [kWh] | {0.0…n} |
PV_walls_west_m2 | West facing wall collector surface area. | float | [m2] | {0.0…n} |
radiation_kWh | Total radiatiative potential. | float | [kWh] | {0.0…n} |
PV_totals
- Path:
outputs/data/potentials/solar/PV_total.csv - File type:
csv - Created by:
photovoltaic - Used by:
optimization
| Variable | Description | Type | Unit | Values |
|---|---|---|---|---|
Area_PV_m2 | Total area of investigated collector. | float | [m2] | {0.0…n} |
Date | Date and time in hourly steps. | date | NA | YYYY-MM-DD |
E_PV_gen_kWh | Total electricity generated by the collector. | float | [kWh] | {0.0…n} |
PV_roofs_top_E_kWh | Electricity production from photovoltaic panels on roof tops | float | [kWh] | {0.0…n} |
PV_roofs_top_m2 | Collector surface area on roof tops. | float | [m2] | {0.0…n} |
PV_walls_east_E_kWh | Electricity production from photovoltaic panels on east facades | float | [kWh] | {0.0…n} |
PV_walls_east_m2 | Collector surface area on east facades. | float | [m2] | {0.0…n} |
PV_walls_north_E_kWh | Electricity production from photovoltaic panels on north facades | float | [kWh] | {0.0…n} |
PV_walls_north_m2 | Collector surface area on north facades. | float | [m2] | {0.0…n} |
PV_walls_south_E_kWh | Electricity production from photovoltaic panels on south facades | float | [kWh] | {0.0…n} |
PV_walls_south_m2 | Collector surface area on south facades. | float | [m2] | {0.0…n} |
PV_walls_west_E_kWh | Electricity production from photovoltaic panels on west facades | float | [kWh] | {0.0…n} |
PV_walls_west_m2 | West facing wall collector surface area. | float | [m2] | {0.0…n} |
radiation_kWh | Total radiatiative potential. | float | [kWh] | {0.0…n} |
PVT_metadata_results
- Path:
outputs/data/potentials/solar/B001_PVT_sensors.csv - File type:
csv - Created by:
photovoltaic_thermal - Used by: (none)
| Variable | Description | Type | Unit | Values |
|---|---|---|---|---|
area_installed_module_m2 | The area of the building surface covered by one solar panel | float | [m2] | {0.0…n} |
AREA_m2 | Surface area. | float | [m2] | {0.0…n} |
array_spacing_m | Spacing between solar arrays. | float | [m] | {0.0…n} |
B_deg | Tilt angle of the installed solar panels | float | [deg] | {0.0…n} |
BUILDING | Unique building ID. It must start with a letter. | string | [-] | alphanumeric |
CATB | Category according to the tilt angle of the panel | int | [-] | {0…n} |
CATGB | Category according to the annual radiation on the panel surface | int | [-] | {0…n} |
CATteta_z | Category according to the surface azimuth of the panel | int | [-] | {0…n} |
intersection | flag to indicate whether this surface is intersecting with another surface (0: no intersection, 1: intersected) | int | [-] | {0, 1} |
orientation | Orientation of the surface (north/east/south/west/top) | string | [-] | {north, south, west, east, top} |
SURFACE | Unique surface ID for each building exterior surface. | string | [-] | alphanumeric |
surface | Unique surface ID for each building exterior surface. | string | [-] | alphanumeric |
surface_azimuth_deg | Azimuth angle of the panel surface e.g. south facing = 180 deg | float | [deg] | {0.0…n} |
tilt_deg | Tilt angle of roof or walls | float | [deg] | {0.0…n} |
total_rad_Whm2 | Total radiatiative potential of a given surfaces area. | float | [Wh/m2] | {0.0…n} |
TYPE | Surface typology. | string | [-] | {walls, roofs} |
type_orientation | Concatenated surface type and orientation. | string | [-] | {walls_east, walls_south, walls_north, walls_west, roofs_top} |
Xcoor | Describes the position of the x vector. | float | [-] | {0.0…n} |
Xdir | Directional scalar of the x vector. | float | [-] | {-1.0…1.0} |
Ycoor | Describes the position of the y vector. | float | [-] | {0.0…n} |
Ydir | Directional scalar of the y vector. | float | [-] | {-1.0…1.0} |
Zcoor | Describes the position of the z vector. | float | [-] | {0.0…n} |
Zdir | Directional scalar of the z vector. | float | [-] | {-1.0…1.0} |
PVT_results
- Path:
outputs/data/potentials/solar/B001_PVT.csv - File type:
csv - Created by:
photovoltaic_thermal - Used by: (none)
| Variable | Description | Type | Unit | Values |
|---|---|---|---|---|
Area_PVT_m2 | Total area of investigated collector. | float | [m2] | {0.0…n} |
Date | Date and time in hourly steps. | date | [datetime] | YYYY-MM-DD |
E_PVT_gen_kWh | Total electricity generated by the collector. | float | [kWh] | {0.0…n} |
Eaux_PVT_kWh | Auxiliary electricity consumed by the collector. | float | [kWh] | {0.0…n} |
mcp_PVT_kWperC | Capacity flow rate (mass flow* specific heat capacity) of the hot water delivered by the collector. | float | [kW/C] | {0.0…n} |
PVT_roofs_top_E_kWh | Electricity production from photovoltaic-thermal panels on roof tops | float | [kWh] | {0.0…n} |
PVT_roofs_top_m2 | Collector surface area on roof tops. | float | [m2] | {0.0…n} |
PVT_roofs_top_Q_kWh | Heat production from photovoltaic-thermal panels on roof tops | float | [kWh] | {0.0…n} |
PVT_walls_east_E_kWh | Electricity production from photovoltaic-thermal panels on east facades | float | [kWh] | {0.0…n} |
PVT_walls_east_m2 | Collector surface area on east facades. | float | [m2] | {0.0…n} |
PVT_walls_east_Q_kWh | Heat production from photovoltaic-thermal panels on east facades | float | [kWh] | {0.0…n} |
PVT_walls_north_E_kWh | Electricity production from photovoltaic-thermal panels on north facades | float | [kWh] | {0.0…n} |
PVT_walls_north_m2 | Collector surface area on north facades. | float | [m2] | {0.0…n} |
PVT_walls_north_Q_kWh | Heat production from photovoltaic-thermal panels on north facades | float | [kWh] | {0.0…n} |
PVT_walls_south_E_kWh | Electricity production from photovoltaic-thermal panels on south facades | float | [kWh] | {0.0…n} |
PVT_walls_south_m2 | Collector surface area on south facades. | float | [m2] | {0.0…n} |
PVT_walls_south_Q_kWh | Heat production from photovoltaic-thermal panels on south facades | float | [kWh] | {0.0…n} |
PVT_walls_west_E_kWh | Electricity production from photovoltaic-thermal panels on west facades | float | [kWh] | {0.0…n} |
PVT_walls_west_m2 | West facing wall collector surface area. | float | [m2] | {0.0…n} |
PVT_walls_west_Q_kWh | Heat production from photovoltaic-thermal panels on west facades | float | [kWh] | {0.0…n} |
Q_PVT_gen_kWh | Total heat generated by the collector. | float | [kWh] | {0.0…n} |
Q_PVT_l_kWh | Collector heat loss. | float | [kWh] | {0.0…n} |
radiation_kWh | Total radiatiative potential. | float | [kWh] | {0.0…n} |
T_PVT_re_C | Collector hot water return temperature. | float | [C] | {0.0…n} |
T_PVT_sup_C | Collector heating supply temperature. | float | [C] | {0.0…n} |
PVT_total_buildings
- Path:
outputs/data/potentials/solar/PVT_total_buildings.csv - File type:
csv - Created by:
photovoltaic_thermal - Used by: (none)
| Variable | Description | Type | Unit | Values |
|---|---|---|---|---|
Area_PVT_m2 | Total area of investigated collector. | float | [m2] | {0.0…n} |
E_PVT_gen_kWh | Total electricity generated by the collector. | float | [kWh] | {0.0…n} |
Eaux_PVT_kWh | Auxiliary electricity consumed by the collector. | float | [kWh] | {0.0…n} |
name | Unique building ID. | string | [-] | alphanumeric |
PVT_roofs_top_E_kWh | Electricity production from photovoltaic-thermal panels on roof tops | float | [kWh] | {0.0…n} |
PVT_roofs_top_m2 | Collector surface area on roof tops. | float | [m2] | {0.0…n} |
PVT_roofs_top_Q_kWh | Heat production from photovoltaic-thermal panels on roof tops | float | [kWh] | {0.0…n} |
PVT_walls_east_E_kWh | Electricity production from photovoltaic-thermal panels on east facades | float | [kWh] | {0.0…n} |
PVT_walls_east_m2 | Collector surface area on east facades. | float | [m2] | {0.0…n} |
PVT_walls_east_Q_kWh | Heat production from photovoltaic-thermal panels on east facades | float | [kWh] | {0.0…n} |
PVT_walls_north_E_kWh | Electricity production from photovoltaic-thermal panels on north facades | float | [kWh] | {0.0…n} |
PVT_walls_north_m2 | Collector surface area on north facades. | float | [m2] | {0.0…n} |
PVT_walls_north_Q_kWh | Heat production from photovoltaic-thermal panels on north facades | float | [kWh] | {0.0…n} |
PVT_walls_south_E_kWh | Electricity production from photovoltaic-thermal panels on south facades | float | [kWh] | {0.0…n} |
PVT_walls_south_m2 | Collector surface area on south facades. | float | [m2] | {0.0…n} |
PVT_walls_south_Q_kWh | Heat production from photovoltaic-thermal panels on south facades | float | [kWh] | {0.0…n} |
PVT_walls_west_E_kWh | Electricity production from photovoltaic-thermal panels on west facades | float | [kWh] | {0.0…n} |
PVT_walls_west_m2 | West facing wall collector surface area. | float | [m2] | {0.0…n} |
PVT_walls_west_Q_kWh | Heat production from photovoltaic-thermal panels on west facades | float | [kWh] | {0.0…n} |
Q_PVT_gen_kWh | Total heat generated by the collector. | float | [kWh] | {0.0…n} |
Q_PVT_l_kWh | Collector heat loss. | float | [kWh] | {0.0…n} |
radiation_kWh | Total radiatiative potential. | float | [kWh] | {0.0…n} |
PVT_totals
- Path:
outputs/data/potentials/solar/PVT_total.csv - File type:
csv - Created by:
photovoltaic_thermal - Used by:
optimization
| Variable | Description | Type | Unit | Values |
|---|---|---|---|---|
Area_PVT_m2 | Total area of investigated collector. | float | [m2] | {0.0…n} |
Date | Date and time in hourly steps. | date | NA | YYYY-MM-DD |
E_PVT_gen_kWh | Total electricity generated by the collector. | float | [kWh] | {0.0…n} |
Eaux_PVT_kWh | Auxiliary electricity consumed by the collector. | float | [kWh] | {0.0…n} |
mcp_PVT_kWperC | Capacity flow rate (mass flow* specific heat capacity) of the hot water delivered by the collector. | float | [kW/C] | {0.0…n} |
PVT_roofs_top_E_kWh | Electricity production from photovoltaic-thermal panels on roof tops | float | [kWh] | {0.0…n} |
PVT_roofs_top_m2 | Collector surface area on roof tops. | float | [m2] | {0.0…n} |
PVT_roofs_top_Q_kWh | Heat production from photovoltaic-thermal panels on roof tops | float | [kWh] | {0.0…n} |
PVT_walls_east_E_kWh | Electricity production from photovoltaic-thermal panels on east facades | float | [kWh] | {0.0…n} |
PVT_walls_east_m2 | Collector surface area on east facades. | float | [m2] | {0.0…n} |
PVT_walls_east_Q_kWh | Heat production from photovoltaic-thermal panels on east facades | float | [kWh] | {0.0…n} |
PVT_walls_north_E_kWh | Electricity production from photovoltaic-thermal panels on north facades | float | [kWh] | {0.0…n} |
PVT_walls_north_m2 | Collector surface area on north facades. | float | [m2] | {0.0…n} |
PVT_walls_north_Q_kWh | Heat production from photovoltaic-thermal panels on north facades | float | [kWh] | {0.0…n} |
PVT_walls_south_E_kWh | Electricity production from photovoltaic-thermal panels on south facades | float | [kWh] | {0.0…n} |
PVT_walls_south_m2 | Collector surface area on south facades. | float | [m2] | {0.0…n} |
PVT_walls_south_Q_kWh | Heat production from photovoltaic-thermal panels on south facades | float | [kWh] | {0.0…n} |
PVT_walls_west_E_kWh | Electricity production from photovoltaic-thermal panels on west facades | float | [kWh] | {0.0…n} |
PVT_walls_west_m2 | West facing wall collector surface area. | float | [m2] | {0.0…n} |
PVT_walls_west_Q_kWh | Heat production from photovoltaic-thermal panels on west facades | float | [kWh] | {0.0…n} |
Q_PVT_gen_kWh | Total heat generated by the collector. | float | [kWh] | {0.0…n} |
Q_PVT_l_kWh | Collector heat loss. | float | [kWh] | {0.0…n} |
radiation_kWh | Total radiatiative potential. | float | [kWh] | {0.0…n} |
T_PVT_re_C | Collector heating supply temperature. | float | [C] | {0.0…n} |
T_PVT_sup_C | Collector heating supply temperature. | float | [C] | {0.0…n} |
SC_metadata_results
- Path:
outputs/data/potentials/solar/B001_SC_ET_sensors.csv - File type:
csv - Created by:
solar_collector - Used by: (none)
| Variable | Description | Type | Unit | Values |
|---|---|---|---|---|
area_installed_module_m2 | The area of the building surface covered by one solar panel | float | [m2] | {0.0…n} |
AREA_m2 | Surface area. | float | [m2] | {0.0…n} |
array_spacing_m | Spacing between solar arrays. | float | [m] | {0.0…n} |
B_deg | Tilt angle of the installed solar panels | float | [deg] | {0.0…n} |
BUILDING | Unique building ID. It must start with a letter. | string | [-] | alphanumeric |
CATB | Category according to the tilt angle of the panel | int | [-] | {0…n} |
CATGB | Category according to the annual radiation on the panel surface | int | [-] | {0…n} |
CATteta_z | Category according to the surface azimuth of the panel | int | [-] | {0…n} |
intersection | flag to indicate whether this surface is intersecting with another surface (0: no intersection, 1: intersected) | int | [-] | {0, 1} |
orientation | Orientation of the surface (north/east/south/west/top) | string | [-] | {north, south, west, east, top} |
SURFACE | Unique surface ID for each building exterior surface. | string | [-] | alphanumeric |
surface | Unique surface ID for each building exterior surface. | string | [-] | alphanumeric |
surface_azimuth_deg | Azimuth angle of the panel surface e.g. south facing = 180 deg | float | [deg] | {0.0…n} |
tilt_deg | Tilt angle of roof or walls | float | [deg] | {0.0…n} |
total_rad_Whm2 | Total radiatiative potential of a given surfaces area. | float | [Wh/m2] | {0.0…n} |
TYPE | Surface typology. | string | [-] | {walls, roofs} |
type_orientation | Concatenated surface type and orientation. | string | [-] | {walls_east, walls_south, walls_north, walls_west, roofs_top} |
Xcoor | Describes the position of the x vector. | float | [-] | {0.0…n} |
Xdir | Directional scalar of the x vector. | float | [-] | {-1.0…1.0} |
Ycoor | Describes the position of the y vector. | float | [-] | {0.0…n} |
Ydir | Directional scalar of the y vector. | float | [-] | {-1.0…1.0} |
Zcoor | Describes the position of the z vector. | float | [-] | {0.0…n} |
Zdir | Directional scalar of the z vector. | float | [-] | {-1.0…1.0} |
SC_results
- Path:
outputs/data/potentials/solar/B001_SC_ET.csv - File type:
csv - Created by:
solar_collector - Used by:
decentralized
| Variable | Description | Type | Unit | Values |
|---|---|---|---|---|
Area_SC_m2 | Total area of investigated collector. | float | [m2] | {0.0…n} |
Date | Date and time in hourly steps. | date | NA | YYYY-MM-DD |
Eaux_SC_kWh | Auxiliary electricity consumed by the collector. | float | [kWh] | {0.0…n} |
mcp_SC_kWperC | Capacity flow rate (mass flow* specific heat capacity) of the hot water delivered by the collector. | float | [kW/C] | {0.0…n} |
Q_SC_gen_kWh | Total heat generated by the collector. | float | [kWh] | {0.0…n} |
Q_SC_l_kWh | Collector heat loss. | float | [kWh] | {0.0…n} |
radiation_kWh | Total radiatiative potential. | float | [kWh] | {0.0…n} |
SC_ET_roofs_top_m2 | Collector surface area on roof tops. | float | [m2] | {0.0…n} |
SC_ET_roofs_top_Q_kWh | Heat production from solar collectors on roof tops | float | [kWh] | {0.0…n} |
SC_ET_walls_east_m2 | Collector surface area on east facades. | float | [m2] | {0.0…n} |
SC_ET_walls_east_Q_kWh | Heat production from solar collectors on east facades | float | [kWh] | {0.0…n} |
SC_ET_walls_north_m2 | Collector surface area on north facades. | float | [m2] | {0.0…n} |
SC_ET_walls_north_Q_kWh | Heat production from solar collectors on north facades | float | [kWh] | {0.0…n} |
SC_ET_walls_south_m2 | Collector surface area on south facades. | float | [m2] | {0.0…n} |
SC_ET_walls_south_Q_kWh | Heat production from solar collectors on south facades | float | [kWh] | {0.0…n} |
SC_ET_walls_west_m2 | Collector surface area on west facades. | float | [m2] | {0.0…n} |
SC_ET_walls_west_Q_kWh | Heat production from solar collectors on west facades | float | [kWh] | {0.0…n} |
T_SC_re_C | Collector hot water return temperature. | float | [C] | {0.0…n} |
T_SC_sup_C | Collector hot water supply temperature. | float | [C] | {0.0…n} |
SC_total_buildings
- Path:
outputs/data/potentials/solar/SC_ET_total_buildings.csv - File type:
csv - Created by:
solar_collector - Used by: (none)
| Variable | Description | Type | Unit | Values |
|---|---|---|---|---|
Area_SC_m2 | Total area of investigated collector. | float | [m2] | {0.0…n} |
Eaux_SC_kWh | Auxiliary electricity consumed by the collector. | float | [kWh] | {0.0…n} |
name | Unique building ID. | string | [-] | alphanumeric |
Q_SC_gen_kWh | Total heat generated by the collector. | float | [kWh] | {0.0…n} |
Q_SC_l_kWh | Collector heat loss. | float | [kWh] | {0.0…n} |
radiation_kWh | Total radiatiative potential. | float | [kWh] | {0.0…n} |
SC_ET_roofs_top_m2 | Roof top collector surface area. | float | [m2] | {0.0…n} |
SC_ET_roofs_top_Q_kWh | Heat production from solar collectors on roof tops | float | [kWh] | {0.0…n} |
SC_ET_walls_east_m2 | East facing wall collector surface area. | float | [m2] | {0.0…n} |
SC_ET_walls_east_Q_kWh | Heat production from solar collectors on east facades | float | [kWh] | {0.0…n} |
SC_ET_walls_north_m2 | North facing wall collector surface area. | float | [m2] | {0.0…n} |
SC_ET_walls_north_Q_kWh | Heat production from solar collectors on west facades | float | [kWh] | {0.0…n} |
SC_ET_walls_south_m2 | South facing wall collector surface area. | float | [m2] | {0.0…n} |
SC_ET_walls_south_Q_kWh | Heat production from solar collectors on south facades | float | [kWh] | {0.0…n} |
SC_ET_walls_west_m2 | West facing wall collector surface area. | float | [m2] | {0.0…n} |
SC_ET_walls_west_Q_kWh | Heat production from solar collectors on west facades | float | [kWh] | {0.0…n} |
SC_totals
- Path:
outputs/data/potentials/solar/SC_FP_total.csv - File type:
csv - Created by:
solar_collector - Used by:
optimization
| Variable | Description | Type | Unit | Values |
|---|---|---|---|---|
Area_SC_m2 | Collector surface area on south facades. | float | [m2] | {0.0…n} |
Date | Date and time in hourly steps. | date | NA | YYYY-MM-DD |
Eaux_SC_kWh | Auxiliary electricity consumed by the collector. | float | [kWh] | {0.0…n} |
mcp_SC_kWperC | Capacity flow rate (mass flow* specific heat capacity) of the hot water delivered by the collector. | float | [kW/C] | {0.0…n} |
Q_SC_gen_kWh | Total heat generated by the collector. | float | [kWh] | {0.0…n} |
Q_SC_l_kWh | Collector heat loss. | float | [kWh] | {0.0…n} |
radiation_kWh | Total radiatiative potential. | float | [kWh] | {0.0…n} |
SC_FP_roofs_top_m2 | Collector surface area on roof tops. | float | [m2] | {0.0…n} |
SC_FP_roofs_top_Q_kWh | Heat production from solar collectors on roof tops | float | [kWh] | {0.0…n} |
SC_FP_walls_east_m2 | Collector surface area on east facades. | float | [m2] | {0.0…n} |
SC_FP_walls_east_Q_kWh | Heat production from solar collectors on east facades | float | [kWh] | {0.0…n} |
SC_FP_walls_north_m2 | Collector surface area on north facades. | float | [m2] | {0.0…n} |
SC_FP_walls_north_Q_kWh | Heat production from solar collectors on north facades | float | [kWh] | {0.0…n} |
SC_FP_walls_south_m2 | Collector surface area on south facades. | float | [m2] | {0.0…n} |
SC_FP_walls_south_Q_kWh | Heat production from solar collectors on south facades | float | [kWh] | {0.0…n} |
SC_FP_walls_west_m2 | Collector surface area on west facades. | float | [m2] | {0.0…n} |
SC_FP_walls_west_Q_kWh | Heat production from solar collectors on west facades | float | [kWh] | {0.0…n} |
T_SC_re_C | Collector hot water return temperature. | float | [C] | {0.0…n} |
T_SC_sup_C | Collector hot water supply temperature. | float | [C] | {0.0…n} |